Photo | Mfr. Part # | Stock | Price | Quantity | Datasheet | Packaging | Series | ProductStatus | FilterType | Configuration | Voltage-RatedDC | Voltage-RatedAC | Voltage-RatedAC(PhasetoGround/Neutral) | Voltage-RatedAC(PhasetoPhase) | Current | Frequency-Operating | Applications | ApprovalAgency | OperatingTemperature | MountingType | TerminationStyle |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
FN258HV-100-35LINE FILTER 100A CHASSIS MOUNT |
2797 | 669.58 |
Add To CartInquiry Now |
Datasheet |
Tray | FN 258 | Not For New Designs | Three Phase (Delta) | Two Stage | - | - | 400 V | 690 V | 100 A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | |
FN256-120-35LINE FILTER 120A CHASSIS MOUNT |
2779 | 675.82 |
Add To CartInquiry Now |
Datasheet |
Tray | FN 256 | Not For New Designs | Three Phase (Wye) | Single Stage | - | - | 277 V | 480 V | 120 A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | |
B84143A0120R021FILTER POWER LINE 120A 440/760V |
3501 | 676.48 |
Add To CartInquiry Now |
Datasheet |
Bulk | B84143A | Active | Three Phase (Delta) | Single Stage | - | 760V, 440V | - | - | 120 A | 50 ~ 60Hz | Inverters, Power Drive Systems | cUL, UL | - | Chassis Mount | Terminal Block, Threaded Post (M10) | |
B84144A0120R000FILTER POWER LINE 120A 250/440V |
3169 | 676.84 |
Add To CartInquiry Now |
Datasheet |
Bulk | B84144 | Active | Three Phase (Wye) | Single Stage | - | 440V, 250V | 250 V | 440 V | 120 A | 50 ~ 60Hz | General Purpose | UL | - | Chassis Mount | Terminal Block, Threaded Post (M10) | |
F3600T080LINE FILTER 600VAC 80A CHASS MNT |
3342 | 679.90 |
Add To CartInquiry Now |
Datasheet |
Box | F3600 | Active | Three Phase (Wye) | Two Stage | - | 600V | - | - | 80 A | 50/60Hz | General Purpose | UR | - | Chassis Mount | Terminal Block | |
FLLE2400APXI1LINE FILTER 1.2KVDC 400A CHASSIS |
3204 | 684.95 |
Add To CartInquiry Now |
Datasheet |
Bulk | FLLE2 | Active | DC | Single Stage | 1200V (1.2kV) | - | - | - | 400 A | - | Photovoltaic Inverter | EN, UL | -40°C ~ 100°C | Chassis Mount | Terminal Post | |
RTCN-5150LINE FILTER 500VDC/VAC 150A CHAS |
3994 | 693.83 |
Add To CartInquiry Now |
Datasheet |
Bulk | RTCN | Active | Three Phase (Delta) | Single Stage | 500V | 500V | - | - | 150 A | - | General Purpose | EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | |
FTA-80-104-HLINE FILTER 500VAC 80A CHASSIS |
2356 | 697.05 |
Add To CartInquiry Now |
Datasheet |
Box | FTA | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 80 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | |
FTA-80-104-SLINE FILTER 500VAC 80A CHASSIS |
3798 | 697.05 |
Add To CartInquiry Now |
Datasheet |
Box | FTA | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 80 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | |
FTA-80-155-HLINE FILTER 500VAC 80A CHASSIS |
3921 | 697.05 |
Add To CartInquiry Now |
Datasheet |
Box | FTA | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 80 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | |
FTA-80-223-HLINE FILTER 500VAC 80A CHASSIS |
2213 | 697.05 |
Add To CartInquiry Now |
Datasheet |
Box | FTA | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 80 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | |
FTA-80-683-HLINE FILTER 500VAC 80A CHASSIS |
3301 | 697.05 |
Add To CartInquiry Now |
Datasheet |
Box | FTA | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 80 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | |
B84142C0320S081LINE FILTER 1.5KVDC 320A CHASSIS |
3867 | 698.65 |
Add To CartInquiry Now |
Datasheet |
Bulk | B84142C | Active | DC | Two Stage | 1500V (1.5kV) | - | - | - | 320 A | 50 ~ 60Hz | Converter | cUL, cUR, UL,UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | |
RSEN-2150LINE FILTER 250VDC/VAC 150A CHAS |
3431 | 699.13 |
Add To CartInquiry Now |
Datasheet |
Bulk | RSEN | Active | Single Phase | Single Stage | 250V | 250V | - | - | 150 A | - | General Purpose | - | -25°C ~ 85°C | Chassis Mount | Terminal Block | |
FLLD4160ATHT7LINE FILTER 160A CHASS MNT |
3553 | 699.23 |
Add To CartInquiry Now |
Datasheet |
Bulk | FLLD3 | Active | Three Phase (Wye) | Single Stage | - | - | 305 V | 530 V | 160 A | 50/60Hz | General Purpose | ENEC, UL | -25°C ~ 100°C | Chassis Mount | Terminal Block | |
FTA-100-104-HLINE FILTER 500VAC 100A CHASSIS |
3471 | 703.16 |
Add To CartInquiry Now |
Datasheet |
Box | FTA | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 100 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | |
FTA-100-155-HLINE FILTER 500VAC 100A CHASSIS |
2697 | 703.16 |
Add To CartInquiry Now |
Datasheet |
Box | FTA | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 100 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | |
FTA-100-223-HLINE FILTER 500VAC 100A CHASSIS |
3074 | 703.16 |
Add To CartInquiry Now |
Datasheet |
Box | FTA | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 100 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | |
FTA-100-683-HLINE FILTER 500VAC 100A CHASSIS |
3279 | 703.16 |
Add To CartInquiry Now |
Datasheet |
Box | FTA | Active | Three Phase (Wye) | Single Stage | - | 500V | - | - | 100 A | 50/60Hz | General Purpose | cURus, VDE | -40°C ~ 85°C | Chassis Mount | Terminal Block | |
B84142J0320S081LINE FLTR 1KVDC 600VAC 320A CHAS |
3171 | 704.93 |
Add To CartInquiry Now |
Datasheet |
Box | B84142 | Active | DC | Two Stage | 1000V (1kV) | 600V | - | - | 320 A | - | Photovoltaic Inverter | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post |